IN STOCK & AVAILABLE FOR IMMEDIATE DISPATCH

LogTag Vaccine Logger Set

Designed for Vaccine Temperature Monitoring

While regular temperature loggers measure the temperature of the air in the vaccine fridge, a temperature logger placed into a vial of liquid better mimics the temperature of liquid vaccines. This means that fluctuations between minimum and maximum will be lower.

These sets contain a logger, a probe, and a leakproof vial with 60ml of propylene glycol, (a liquid with a very low freezing temperature). Available with or without a LogTag reader.

 

A$209.00A$409.00 incl. GST

A complete vaccine monitoring solution

When placed in the refrigerator with vaccines, this set will accurately log their actual temperature, rather than the air temperature in the refrigerator.

This set contains:

  • Premium LogTag with Display, External Probe and Replaceable Battery
  • ST100J External Probe
  • Glycol Buffer Leak-Proof Vial (glycol not included)
  • LogTag Analyzer Software on CD
  • USB Interface Reader

Also available without the USB Reader and Software.

How it works

When a refrigerator door is opened, the air temperature in the refrigerator may rise quite rapidly, but the temperature of stored liquid vaccines will be much slower to react. Logging the temperature of a liquid will therefore give a much more accurate record of what your vaccines actually experienced.

This set has a LogTag attached to a probe that is immersed in glycol. It mimics the actual temperature experienced by vaccines in your refrigerator.

Note: The glycol (antifreeze) to go in the vial is not supplied but is readily available.

LogTag with glycol

LogTag Specifications

PREMIUM

Product ModelTRED30-16R (Replaceable Battery)
External Sensor Measurement Range-40°C to +99°C (-40°F to +210°F).
Operating Temperature Range-30°C to +60°C (-22°F to +140°F).
Storage Temperature Range-10°C to +40°C (14°F to +104°F).
Rated Temperature Reading AccuracyBetter than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F).
Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F).
Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F).
Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F).
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F).
0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F).
0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F).
0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F).
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction TimeTypically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types.
Recording Capacity15,905 temperature readings. 66 days @ 6min logging.
Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics.
Sampling IntervalConfigurable from 30 seconds to hourly.
Logging Start OptionsPush button start or specific date & time. Optional start delay of up to 18 hours.
Recording IndicationState indicator “RECORDING”.
Download TimeTypically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used.
EnvironmentalIP61 (when vertically mounted or hung).
Power Source3V CR2032 (LiMnO2) coin cell battery, user replaceable.
Battery LifeTypically 1 year of operation.
NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time.
Download data monthly.
NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible.
Real Time ClockBuilt-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Standard Remote Sensor Cable LengthStandard: 1.5m (4’11″).
Extended: 3m (9’10″) (Recommended maximum).
Remote Sensor Cable TypePTFE (FDA food contact rated), coaxial.
Size93mm(H) x 54.5mm(W) x 8.6mm(T).
Weight41g.
Case MaterialPolycarbonate.
Compliance and CertificationsFDA CFR21 Part 11
FCC EMC Directive
CE EMC DirectivesConforms to RoHS

STANDARD

Product Model TREX-8
External Sensor Measurement Range -40°C to +99°C (-40°F to +210°F)
Operating Temperature Range -40°C to +85°C (-40°F to +185°F).
Storage Temperature Range -10°C to +55°C (14°F to +131°F).
Rated Temperature Reading Accuracy Better than ±0.5°C for -10°C to +40°C. Better than ±0.7°C for -10°C to -30°C and +40°C to +60°C. Better than ±0.8°C for -30°C to -40°C and +60°C to +80°C. Better than ±1.0°C for +80°C to +99°C. Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below. Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution Less than 0.1°C for -40°C to +40°C. Less than 0.2°C for +40°C to +80°C. Less than 0.6°C for +80°C to +99°C. Please see the Rated Native Resolution chart below. LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types.
Recording Capacity 8031 temperature readings. 53 days @ 10min logging, 80 days @ 15min logging.
Sampling Interval Configurable from 30 seconds to several hours.
Logging Start Options Push button start or specific date & time. Optional start delay of up to 18 hours.
Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
Download Time Typically less than 5 seconds for full memory (8031 readings), depending on computer or readout device used.
Environmental IP61.
Power Source 3V Li-Mg Battery.
Battery Life 2 – 3 years of normal use (based on 15 minute logging, download data monthly).
Real Time Clock Built-in real time clock. Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Standard Remote Sensor Cable Length Standard: 1.5m (4’11″). Extended: 3m (9’10″) (Recommended maximum).
Remote Sensor Cable Type PTFE (FDA food contact rated), coaxial.
Size 86mm(H) x 54.5mm(W) x 8.6mm(T).
Weight 36g (without External Probe).
Case Material Polycarbonate.
Compliance and Certifications FDA CFR21 Part 11 FCC EMC DirectiveCE EMC DirectivesConforms to RoHS